Question # 14

When referring to the internal mounting space in racks, equipment manufactures generally refer to standardized height of electronic modules “U” or “RU”. What is the height of 1 “U” or “RU”?

Options:

A.

19 inches (60 cm)

B.

24 inches (80 cm)

C.

1.75 inches (4.445 cm)

D.

3.5 inches (8.59 crn)

Buy Now
Question # 15

Which Class of Fires involves cooking appliances?

Options:

A.

Class A

B.

Class B

C.

Class C

D.

Class K

Buy Now
Question # 16

Can Electro Magnetic Fields (EMF) cause data centre failures?

Options:

A.

Yes, high levels of EMF can cause data centre failures.

B.

No, only power issues will cause data centre failures.

C.

No, only cooling issues will cause data centre failures.

D.

Yes, but only EMF caused by lightning strikes.

Buy Now
Question # 17

What is the best practice for cutting holes in the raised floor tile?

Options:

A.

Anywhere as data centre tiles are designed to allow cut-outs anywhere.

B.

Draw a cross on the tile and when making a cut-out do not touch a line and avoid the corners.

C.

Draw a line in the middle of the tile and never touch the line when making the cut.

D.

Cut the tiles at the corner so the pedestals can be used as a vertical cable manager.

Buy Now
Question # 18

What are the four main components of a refrigeration circuit?

Options:

A.

Evaporation, membrane filter, monitor sensor, pressure valve

B.

Evaporator, compressor, condenser, expansion valve

C.

Condenser, expansion valve, buffer tank, de-icing unit

D.

Thermostat, monitoring interface, indoor unit, outdoor unit

Buy Now
Question # 19

Starting from which Rating does the requirement of Concurrently Maintainability becomes relevant?

Options:

A.

Rated-4

B.

Rated-3

C.

Rated-2

D.

Rated-1

Buy Now
Question # 20

Which Class of Fires involves energized electrical equipment?

Options:

A.

Class A

B.

Class B

C.

Class C

D.

Class K

Buy Now
Question # 21

systems are designed specifically to protect the structure of a building.

Options:

A.

Pro-inert

B.

Inergen

C.

Water sprinkler

D.

Total Flooding

Buy Now
Question # 22

What should be taken into consideration when using patch cables?

Options:

A.

The patch cable should always be the same of a lower class the structured cable.

B.

The patch cable should always be the same or a higher class the structured cable.

C.

Patch cables can only be used in combination with flat patch panels.

D.

Patch cables can only be used in combination with angled patch panels.

Buy Now
Question # 23

Which one of the following is an example of Indirect Cost?

Options:

A.

Legal fees

B.

Damaged brand perception

C.

System recovery

D.

Cost revenues

Buy Now