Big Cyber Monday Sale 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: Board70

D-PSC-DY-23 Exam Dumps - EMC Storage Administrator Questions and Answers

Question # 4

What Is the maximum number of criteria blocks with an OR condition that can be configured in a single file pool policy?

Options:

A.

5

B.

3

C.

1

D.

2

Buy Now
Question # 5

In a Dell PowerScale environment, what is a requirement to join multiple, untrusted Active Directory (AD) authentication sources to an access zone?

Options:

A.

All untrusted AD provider instances must exist in all access zones

B.

Only one of the AD provider instances can exist in a zone at one time

C.

A common /'ifs tree is required for all access zones

D.

Must only join Active Directory domains in the same forest

Buy Now
Question # 6

Which command shows the node running as the job coordinator?

Options:

A.

isi job statistics

B.

isi job status

C.

isi job status -v

D.

isi job statistics view -v

Buy Now
Question # 7

When configuring NTP on a 16-node Gen 6 cluster, how many chimer nodes are automatically configured on the duster?

Options:

A.

3

B.

6

C.

1

D.

16

Buy Now
Question # 8

When reviewing the actual protection output of N+-4/2, what does the number "2" represent?

Options:

A.

Number of FEC stripe units per file system

B.

Number of drives used per stripe

C.

Number of FEC stripe units per stripe

D.

Number of drives used per node

Buy Now
Question # 9

A Dell PowerScale cluster has ten A200 nodes and the node pool data protection level is set to N+2. The data access pattern is currently set to streaming If the data access pattern is changed to concurrency, how many stripes for a 1 MB file are moved to other drives?

Options:

A.

4

B.

0

C.

2

D.

6

Buy Now
Question # 10

What is the recommended maximum number of clusters and nodes that a single insightlCJ instance should simultaneously monitor?

Options:

A.

3 clusters or 60 nodes

B.

5 clusters or 120 nodes

C.

8 clusters or 150 nodes

D.

6 clusters or 140 nodes

Buy Now
Question # 11

A company deployed an Isilon cluster that consists of eight nodes connected to a main production subnet by all available 10GB ports. Later, the company decided to implement a disaster recovery solution with a separate replication subnet. During the reconfiguration, one of the 10Gb ports from each of the nodes 1-4 was moved into the new pool and SBR was activated.

After activating the replication policies, the administrator noticed that the main production ports on nodes 1-4 reached the bandwidth limit. What is a possible reason for this behavior?

Options:

A.

Default gateway for the replication subnet has a higher priority value.

B.

Default gateway for the replication subnet is not specified.

C.

Default gateway for the replication subnet has a lower priority value.

D.

Main production ports have a smaller bandwidth limit than replication ports.

Buy Now
Question # 12

A company wants to re-use HD400 nodes into a new cluster with OneFS 8.2.0. What is the minimum number of HD400 nodes required?

Options:

A.

3

B.

4

C.

5

D.

6

Buy Now
Question # 13

What is the recommended networking design approach when planning subnets?

Options:

A.

Use a common subnet for data, replication and backup, and use a dedicated subnet for management.Assign the lowest priority gateway number for the management subnet.

B.

Use a common subnet for management, data, replication and backup.Assign a random priority gateway number for the subnet.

C.

Use a common subnet for data and management and a common subnet for replication and backup.Assign the lowest priority gateway number for the management subnet.

D.

Use dedicated subnets for management, data, replication and backup.Assign the lowest priority gateway number for the data subnet.

Buy Now
Exam Code: D-PSC-DY-23
Exam Name: Dell PowerScale Deploy 2023
Last Update: Dec 7, 2025
Questions: 102
D-PSC-DY-23 pdf

D-PSC-DY-23 PDF

$25.5  $84.99
D-PSC-DY-23 Engine

D-PSC-DY-23 Testing Engine

$28.5  $94.99
D-PSC-DY-23 PDF + Engine

D-PSC-DY-23 PDF + Testing Engine

$40.5  $134.99