Weekend Special - 75% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: certbig75

H13-629_V3.0 Exam Dumps - Huawei HCIE-Storage Questions and Answers

Question # 4

When using Huawei OceanStor BCManager eReplication DR management software to implement DR protection, you can perform DR drills periodically. Which of the following operations are required during DR drills?

Options:

A.

Start a DR application.

B.

Switch the replication relationship.

C.

Formulate a recovery plan.

D.

Synchronize incremental data.

Buy Now
Question # 5

A financial customer has purchased multiple Huawei flash storage devices for service deployment. Which of the following statements is false about service system I/O characteristics in financial scenarios?

Options:

A.

The OLAP database mainly involves sequential read of large I/Os. The amount of data processed per batch determines hot data areas.

B.

Backup and archiving services mainly involve sequential large I/Os. Writes are involved in backup and archiving services, and reads are involved in restoration services.

C.

Document imaging services mainly involve sequential read of large I/Os, a few metadata operations, and 90% GB-level large file write operations.

D.

The OLTP database mainly involves random small I/Os and a few sequential write I/Os. There are more reads than writes, and hot data areas are obvious.

Buy Now
Question # 6

During data migration using SmartMigration of Huawei flash storage, LUN information exchange changes the mapping between LUNs and data volumes. Which of the following statements about the mapping are true?

Options:

A.

After LUN information is exchanged, the host uses the source LUN ID to identify the target data volume.

B.

After the pair is split, the host I/O data is written only to the target LUN, and dual-write is not performed.

C.

Before LUN information is exchanged, the host uses the source LUN ID to identify the source LUN.

D.

During LUN information exchange, the LUN IDs remain unchanged, and the data volume IDs of the source and target LUNs are exchanged.

Buy Now
Question # 7

An enterprise has deployed a Huawei all-flash storage system to carry service data. During routine O & M, an engineer discovered a steady yellow link indicator on an Ethernet port of the storage device. Then, the engineer logged in to DeviceManager, checked the rear view of the storage device, and found that the running status of the Ethernet port was " Link down " . In this scenario, the problem may be caused by incorrect IP address configuration for either the logical port or the service network port on the application server.

Options:

A.

TRUE

B.

FALSE

Buy Now
Question # 8

Huawei OceanStor Dorado all-flash storage uses RAID 2.0+ to implement fine-grained division and evenly distributes data of all LUNs to each SSD. If 3.84 TB SSDs are configured, which of the following is the default chunk size?

Options:

A.

4MB

B.

4KB

C.

8MB

D.

8KB

Buy Now
Question # 9

When SmartVirtualization is configured for Huawei all-flash storage to take over Huawei heterogeneous storage online, which of the following is optional?

Options:

A.

Switching over host paths

B.

Mapping eDevLUNs to application servers

C.

Checking the heterogeneous storage system

D.

Adding route information

Buy Now
Question # 10

Storage engineers can manage and maintain the storage system on the CU. For example, as a super administrator, run the______command on the CU to view historical version information of the storage

system. (Enter a complete command.)

Options:

Buy Now
Question # 11

What functions can the virtual firewall service provide for the Datacenter Virtualization Solution (DCS) multi-tenant service?

Options:

A.

Access control for virtual private clouds (VPCs)

B.

Providing access policies for cloud servers that have the same security protection requirements and that are mutually trusted within a VPC

C.

Establishing a virtual private network (VPN) between a remote user and a VPC

D.

Blacklist and whitelist

Buy Now
Question # 12

An enterprise plans to purchase OceanStor Pacific storage and is not sure whether to use Distributed Parallel Client (DPC) or Network File System (NFS) for host connection. Which of the following statements about the differences between the two is true?

Options:

A.

NFS supports POSIX and MPI-IO protocols.

B.

DPC can implement I/O-level load balancing, ensuring real-time load balancing of storage services.

C.

There is no performance bottleneck on the NFS storage side. Performance is limited only by the performance of a single CPU core on compute nodes.

D.

A single DPC can connect to multiple storage nodes. Data I/Os are cached on the mounted storage node and then written to the destination storage node.

Buy Now
Question # 13

When an engineer is planning the OceanProtect Appliance network, the front-end storage network switches use M-LAG networking. Which front-end storage port mode should be used to ensure that links are not interrupted in the event of a switch port fault?

Options:

A.

Mode3

B.

Mode 4

C.

Model1

D.

Mode 2

Buy Now
Exam Code: H13-629_V3.0
Exam Name: HCIE-Storage V3.0
Last Update: Oct 4, 2026
Questions: 60
H13-629_V3.0 pdf

H13-629_V3.0 PDF

$21.25  $84.99
H13-629_V3.0 Engine

H13-629_V3.0 Testing Engine

$23.75  $94.99
H13-629_V3.0 PDF + Engine

H13-629_V3.0 PDF + Testing Engine

$33.75  $134.99