Question # 14

Materials acceptable for use in fire-protecting connections in Type IV-A construction includes each of the following except:

Options:

A.

steel plates.

B.

gypsum board.

C.

a coating approved for the required fire endurance time.

D.

additional wood cover applied over the connection.

Buy Now
Question # 15

Periodic special inspection of sealants or adhesives shall be conducted where sealants or adhesives are part of a mass timber building element as designated in the approved construction documents.

All of the following statements are correct in reference to sealants or adhesives in mass timber buildings except:

Options:

A.

Sealants shall meet the requirements of ASTM C920.

B.

Adhesives shall meet the requirements of ASTM D3498.

C.

Special inspection of mass timber sealing requirements also apply to joints.

D.

Sealants at abutting edges and intersection of mass timber buildings need periodic inspections.

Buy Now
Question # 16

In mass timber construction of Type IV-B, each of the following is suitable for use as fireblocking except:

Options:

A.

mineral wool.

B.

one-half-inch gypsum board.

C.

7/16-inch wood structural panels.

D.

mass timber complying with IBC Section 2304.11.

Buy Now
Question # 17

Which of the following is true regarding fire-resistance rating protection provided by noncombustible covering material?

Options:

A.

1/2 in. gypsum board provides 30 minutes

B.

1/2 in. Type X gypsum board provides 40 minutes

C.

5/8 in. gypsum board provides 40 minutes

D.

5/8 in. Type X gypsum board provides 40 minutes

Buy Now
Question # 18

Based on the definition of cross-laminated timber (CLT), panels are manufactured as follows:

Options:

A.

with less than three layers.

B.

with all layers nailed together.

C.

with adjacent layers cross oriented.

D.

with all layers in the same orientation.

Buy Now
Question # 19

What fire-resistance rating is required for floors in Type IV-A, IV-B and IV-C construction?

Options:

A.

1 hour

B.

2 hours

C.

3 hours

D.

4 hours

Buy Now
Question # 20

One code-recognized method for calculating the fire-resistance rating of exposed wood members and decking is:

Options:

A.

ACI 216.1

B.

TMS 0216

C.

ASCE 29 Chapter 5

D.

AWS NDS Chapter 16

Buy Now
Question # 21

Calculated mass timber fire resistance can include each of the following except:

Options:

A.

minimum prescriptive dimensions.

B.

calculated fire resistance of the wood.

C.

fire resistance of noncombustible protection.

D.

combination of calculated fire resistance of the wood and noncombustible protection.

Buy Now
Question # 22

Combustible construction forming concealed spaces shall be protected with noncombustible protection with an assigned time of 40 minutes in which construction type?

Options:

A.

Type IV-A

B.

Type IV-B

C.

Type IV-C

D.

Type IV-HT

Buy Now
Question # 23

Given: Sealants or adhesives need not be provided where they are not a required component of a tested fire resistance rated assembly.

If a sealant is required, it must meet the requirement of ASTM:

Options:

A.

E114

B.

E119

C.

C920

D.

D3498

Buy Now
Exam Name: 93-Tall-Mass-Timber-Buildings
Last Update: Aug 30, 2026
Questions: 80
93-Tall-Mass-Timber-Buildings pdf

93-Tall-Mass-Timber-Buildings PDF

$21.25  $84.99
93-Tall-Mass-Timber-Buildings Engine

93-Tall-Mass-Timber-Buildings Testing Engine

$23.75  $94.99
93-Tall-Mass-Timber-Buildings PDF + Engine

93-Tall-Mass-Timber-Buildings PDF + Testing Engine

$33.75  $134.99