Question # 4

Buildings of Types IV-A, IV-B, and IV-C construction designed to be greater than six stories above grade plane shall meet which of the following requirements for fire safety practices during construction?

Options:

A.

Standpipes shall be provided in accordance with IFC Section 3313.

B.

The IFC specifically requires a portable water supply.

C.

Required exterior wall coverings on all floor levels more than 2 levels below the floor under construction, including mezzanines.

D.

At least two layers of noncombustible protection, where noncombustible protection is required for the building element, on all mass timber more than 4 stories below the uppermost floor under construction.

Buy Now
Question # 5

Which of the following products is not included in the definition of mass timber?

Options:

A.

Solid sawn lumber

B.

Prefabricated wood I-joists

C.

Glued laminated timber

D.

Cross-laminated timber

Buy Now
Question # 6

Which of the following provisions for mass timber used for interior exit and elevator hoistway enclosures is true?

Options:

A.

Type IV-A construction requires at least 80 minutes of the 120-minute fire-resistance rating to be provided by noncombustible protection.

B.

Type IV-B construction requires at least 40 minutes of the 120-minute fire-resistance rating to be provided by noncombustible protection.

C.

Type IV-C construction requires at least 40 minutes of the 60-minute fire-resistance rating to be provided by noncombustible protection.

D.

Type IV-HT construction requires at least 40 minutes of the 60-minute fire-resistance rating to be provided by noncombustible protection.

Buy Now
Question # 7

Given: A building of Type IV-B construction is designed to be greater than six stories above grade plane.

At least one layer of required noncombustible protection shall be installed on all of the following building elements except _____ on all floor levels more than four levels below active mass timber construction before erecting additional floor levels during construction.

Options:

A.

mezzanines

B.

shafts and vertical exit enclosures

C.

floors as required by IBC Section 602.4

D.

wall and ceilings as required by IBC Section 602.4

Buy Now
Question # 8

For Type IV-A, IV-B, and IV-C construction, each of the following materials on the exterior side of mass timber exterior walls is required to be noncombustible except:

Options:

A.

insulation.

B.

exterior cladding.

C.

architectural trim.

D.

water-resistive barrier.

Buy Now
Question # 9

Refer to the exhibit by clicking on the EXHIBIT button above.

If the glulam beam and CLT panels all require a fire-resistance rating of 2 hours, what is the required fire-resistance rating in hours for the structural connections between the glulam and CLT?

Options:

A.

0, since they are hidden fasteners

B.

1

C.

2

D.

3, to provide an additional safety factor

Buy Now
Question # 10

What fire-resistance rating is required for Type IV-C exterior and interior bearing walls?

Options:

A.

1 hour

B.

2 hours

C.

3 hours

D.

4 hours

Buy Now
Question # 11

Which of the following is the best definition of Type IV-B construction?

Options:

A.

100% noncombustible protection on all mass timber surfaces

B.

50% noncombustible protection on the exterior and interior mass timber elements

C.

100% exposed mass timber except: shafts, concealed spaces, and outside of exterior walls

D.

Noncombustible protection on all surfaces of mass timber except for limited exposed mass timber elements

Buy Now
Question # 12

Refer to the figure by clicking on the EXHIBIT button above.

In Type IV-B construction, unprotected portions of mass timber as shown in the Figure is limited to an area equal to not more than what percentage of the base floor area?

Options:

A.

15%

B.

20%

C.

30%

D.

40%

Buy Now
Question # 13

Each of the following is true regarding the fire-resistance rating for exterior bearing walls except:

Options:

A.

Type IV-C must be 1 hour

B.

Type IV-A must be 3 hours

C.

Type IV-B must be 2 hours

D.

Type IV-C must be 2 hours

Buy Now
Exam Name: 93-Tall-Mass-Timber-Buildings
Last Update: Aug 29, 2026
Questions: 80