Spring Sale 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: Board70

API-SIEE Exam Dumps - API ICP Programs Questions and Answers

Question # 4

According to the guide definitions, a junction box used within a control building or instrument enclosure may also be referred to as an:

Options:

A.

interface box

B.

breaker cubicle

C.

bus duct

D.

starter cell

Buy Now
Question # 5

Which switchgear-related item is explicitly identified in the guide table of contents as an inspection topic?

Options:

A.

Cable tray color coding

B.

Metering

C.

Turbine nozzle alignment

D.

Firewater pump casing hardness

Buy Now
Question # 6

According to API 541, totally enclosed machines TEFC, TEPV, TEWAC, and TEAAC are equipped with which of the following?

Options:

A.

Low-point drain

B.

Heat exchanger cooling fan

C.

Bearing RTDs

D.

Surge protectors

Buy Now
Question # 7

According to IEEE C57.12.00, a durable, metal, name plate shall be affixed to each transformer by the:

Options:

A.

manufacturer.

B.

owner.

C.

purchaser.

D.

QA/QC Inspector.

Buy Now
Question # 8

What requirement shall be included in a lockout/tagout procedure?

Options:

A.

An arc flash requirement where a high level of exposure is foreseen

B.

A power testing requirement where a direct exposure situation can be detected

C.

A voltage testing requirement where there might be direct exposure to electrical hazards

D.

A voltage and current testing for direct exposure situations

Buy Now
Question # 9

According to NETA, for low voltage cables a visual inspection must verify that:

Options:

A.

color codes comply with IEEE requirements.

B.

the shield on power cables is properly grounded.

C.

connections are in accordance with the single-line diagram.

D.

all cables are connected to terminals via ring tongue lugs.

Buy Now
Question # 10

Which of the following is identified in the guide as a key MCC design item?

Options:

A.

Ground bus

B.

Transformer conservator

C.

Buchholz relay

D.

Tap changer handle

Buy Now
Question # 11

What is the purpose of labeling the temperature range on electrical equipment used in a Class I hazardous area?

Options:

A.

To verify the process temperature and the equipment temperature have the same Class I rating

B.

To ensure that the equipment maximum temperature does not exceed the autoignition temperature of the specific gas or vapor to be encountered

C.

To ensure the equipment is compatible with the other Class I devices

D.

To verify the maximum process temperature does not exceed high levels

Buy Now
Question # 12

Metallic shielding components such as tapes, wires, or braids shall be connected to a:

Options:

A.

equipment grounding busbar.

B.

low voltage ceramic insulator.

C.

low voltage connector.

D.

center tap of a transformer.

Buy Now
Question # 13

Circuit breakers over 1000 V equipped with stored energy mechanisms shall perform which of the following functions?

Options:

A.

Indicate whether power is available to the circuit breaker

B.

Identify the presence of fault current flow through the circuit breaker

C.

Locate the position of the charging mechanism

D.

Prevent the release of the stored energy unless the mechanism has been fully charged

Buy Now
Exam Code: API-SIEE
Exam Name: Source Inspector Electrical Equipment
Last Update: Mar 20, 2026
Questions: 110
API-SIEE pdf

API-SIEE PDF

$25.5  $84.99
API-SIEE Engine

API-SIEE Testing Engine

$28.5  $94.99
API-SIEE PDF + Engine

API-SIEE PDF + Testing Engine

$40.5  $134.99