Question # 4

A financial customer has purchased two Huawei flash storage devices and installed them in two equipment rooms of a local data center to deploy HyperMetro services. During quorum server network planning, only 10GE quorum links can be used when a single quorum server is deployed. 25GE and Fibre Channel networks cannot be used.

Options:

A.

TRUE

B.

FALSE

Buy Now
Question # 5

Cache policies and configurations are involved in storage-layer performance optimization of Huawei flash storage. Which of the following statements is false about the high and low watermarks of a cache?

Options:

A.

Generally, the low watermark for storing dirty data in the cache should not be too low. The recommended value is 20%.

B.

Generally, the high watermark of the cache should not be too high, and the difference between the high and low watermarks should not be too small.

C.

If the high watermark of the cache is too high, I/O fluctuation and latency increase will occur usually when the current I/O traffic bursts.

D.

If the high watermark of the cache is too high, the write performance will be affected. If the low watermark of the cache is too low, the read performance will be affected.

Buy Now
Question # 6

In a flash storage system, the ports of the cascading interface module or onboard cascading ports on the controller enclosure can only connect to port PI on the disk enclosure.

Options:

A.

TRUE

B.

FALSE

Buy Now
Question # 7

Routine management on Huawei flash storage systems involves power-on and power-off. Which of the following statements is false about power-on and power-off?

Options:

A.

Before powering on the storage system, you need to ensure that all expansion cables are correctly connected. The storage system may work improperly if the connection mode of expansion cables is adjusted after the storage system is powered on.

B.

If none of the controller enclosures in the cluster are powered on, you can log in to the BMC system using the external management IP address of the BMC and run the power-on command to power on all the controller enclosures.

C.

To power on the storage system after an emergency power-off, you need to press the power button on the controller enclosure.

D.

For Huawei OceanStor Dorado 8000 storage, after a controller enclosure is powered on, its cascaded disk enclosures will be automatically powered on.

Buy Now
Question # 8

A school has purchased two Huawei OceanStor Pacific series storage devices for service deployment. An engineer wants to configure the distributed parallel client (DPC) on the storage devices. Which of the following statements is false about the engineer's configuration?

Options:

A.

If upper-layer services require high data security, the engineer needs to set the storage pool type to "Self-encrypting" when creating a converged storage pool.

B.

Before creating a converged storage pool, the engineer must enable the file service for nodes on DeviceManager.

C.

When creating a namespace, the engineer needs to select a security style and application type.

D.

When the storage network is a Remote Direct Memory Access over Converged Ethernet (RoCE) network, the engineer can run the "systemctl stop lldpad.service" command to disable the lldpad service.

Buy Now
Question # 9

An industry customer purchased several Huawei OceanStor Pacific series scale-out storage devices for service deployment, and an engineer configured the SmartMigration feature on the storage devices. Now the engineer wants to change the split mode and migration rate of a SmartMigration task due to changes in service requirements. Which of the following SmartMigration running statuses does not allow the engineer to perform the change?

Options:

A.

Interrupted

B.

Paused

C.

Faulty

D.

Migrating

Buy Now
Question # 10

An industry customer has purchased several Huawei flash storage devices for service deployment. To improve service data reliability, an engineer configures the HyperReplication feature on the storage devices. If the engineer wants to modify the properties of a remote replication pair, which of the following commands cannot be used? (Choose all that apply)

Options:

A.

change hyper_metro_pair general

B.

change hyper_metro_pair start

C.

show consistency_group general

D.

change remote_replication synchronize

Buy Now
Question # 11

A government customer has purchased several Huawei OceanStor Pacific series storage devices. An engineer wants to install the distributed parallel client (DPC) on the storage devices. The operations before DPC installation have been completed. Now, the engineer needs to add DPC nodes. Which of the following statements are true about adding nodes?

Options:

A.

The engineer can add nodes by batch importing nodes or manually adding nodes. In either mode, authentication is not required.

B.

If the engineer selects "Manually Add Node" on DeviceManager, the engineer must enter the management IP address of the node to be added.

C.

If the engineer selects "Manually Add Node" on DeviceManager, the engineer must enter the service IP address of the node to be added.

D.

If the engineer selects "Batch Import Node" on DeviceManager, the engineer must fill in the downloaded template, and upload the template to complete batch import.

Buy Now
Question # 12

If a performance Issue occurs in Huawei flash storage, an engineer can perform optimization operations according to the storage performance optimization process. Which of the following statements is false about the performance optimization process?

Options:

A.

In the information collection phase, the engineer needs to collect basic information about applications and data, such as the impact of application configurations on data, data size, and read/write ratio.

B.

In the test and application phase, the engineer needs to test the configurations to check whether the optimization objective is achieved. If yes, the engineer can put the system into use.

C.

In the optimization analysis phase, the engineer needs to specify the performance optimization objective, find out the performance bottleneck, and identify the parts that play a key role in Improving the system performance.

D.

In the optimization operation phase, the engineer needs to deploy DR for the service system, and needs to modify multiple configuration at a time during the optimization configuration.

Buy Now
Question # 13

In Huawei flash storage, the administrator rote has full control permissions on storage devices. The administrator can power on, power off, and restart devices and create users of different roles.

Options:

A.

TRUE

B.

FALSE

Buy Now