Question # 34

During HPL execution on a DGX cluster, the benchmark fails with " not enough memory " errors despite sufficient physical RAM. Which HPL.dat parameter adjustment is most effective?

Options:

A.

Reduce the problem size while maintaining the same block size.

B.

Set PMAP to 1 to enable process mapping.

C.

Increase block size to 6144 to maximize GPU utilization.

D.

Disable double-buffering via BCAST parameter.

Buy Now
Question # 35

A system administrator noticed a failure on a DGX H100 server. After a reboot, only the BMC is available. What could be the reason for this behavior?

Options:

A.

The network card has no link / connection.

B.

A boot disk has failed.

C.

Multiple GPUs have failed.

D.

There are more than two failed power supplies.

Buy Now
Question # 36

You are leading a project to enhance the energy efficiency of a data center that heavily relies on AI workloads. NVIDIA suggests moving beyond traditional metrics like Power Usage Effectiveness (PUE) to better capture the efficiency of modern data centers. Which strategy should you prioritize?

Options:

A.

Use Power Usage Effectiveness as the primary metric while supplementing it with additional measures of useful work done per unit of energy.

B.

Use watts used as the primary measure of efficiency, as it accurately reflects the power input at any given time.

C.

Develop benchmarks tailored to specific workloads, such as MLPerf for AI applications, to better understand energy use in real-world scenarios.

D.

Focus on integrating kilowatt-hours into existing metrics to better reflect the actual energy used for productive work.

Buy Now
Question # 37

What information does the ' ibnodes ' command display?

Options:

A.

All hosts & switches

B.

All host & server names

C.

All server names

D.

All channel adapters

Buy Now
Question # 38

An InfiniBand administrator needs to run performance benchmarks on new devices added to the fabric. What tool should be used to check the latency?

Options:

A.

tcpdump

B.

ib_write_lat

C.

ibdiagnet

D.

perfmon

Buy Now
Question # 39

An engineer needs to verify NVLink isolation on a single node with 8 GPUs. Which NCCL test configuration stresses switch bisection bandwidth?

Options:

A.

Use NCCL_TESTS_SPLIT= " DIV 8 " with point-to-point tests

B.

Use all_reduce_perf -b 8 -e 16G -f 2 -g 8 with NCCL_TESTS_SPLIT= " AND 0x1 "

C.

Use reduce_scatter_perf -b 8 -e 16G -f 2 -g 4

D.

Use all_reduce_perf -b 8 -e 16G -f 2 -g 8 without splits

Buy Now