ITFAS-Level-1 Exam Dumps - NICET Inspection and Testing of Fire Alarm Systems Questions and Answers

Question # 4

How often are manual fire alarm boxes inspected?

Options:

A.

Monthly

B.

Quarterly

C.

Semiannually

D.

Annually

Buy Now
Question # 5

When testing initiating devices, what is the maximum allowed time for the supervising station to verify receipt of the signal?

Options:

A.

60 seconds

B.

80 seconds

C.

90 seconds

D.

120 seconds

Buy Now
Question # 6

Visible and audible trouble signals shall be indicated at which two of the following locations? (Choose two.)

Options:

A.

Alarm company office

B.

Emergency command center

C.

Fire alarm control unit

D.

Fire department headquarters

Buy Now
Question # 7

Verification of a DACT’s trouble signal to the fire alarm shall be received within a maximum of how many minutes when the primary telephone line is disconnected?

Options:

A.

2

B.

3

C.

4

D.

5

Buy Now
Question # 8

Records of inspections, testing, and maintenance shall be provided in accordance with which section of NFPA 72?

Options:

A.

7.6.6

B.

7.8.2

C.

10.5.3

D.

14.6.3

Buy Now
Question # 9

What is the inspection frequency of supervising station alarm system transmitters?

Options:

A.

Monthly

B.

Quarterly

C.

Semiannually

D.

Annually

Buy Now
Question # 10

When the main power is disconnected, how long should a power supply with emergency voice communication systems work in alarm mode?

Options:

A.

Maximum of 5 minutes

B.

Maximum of 15 minutes

C.

Minimum of 5 minutes

D.

Minimum of 15 minutes

Buy Now
Question # 11

What is the maximum travel distance between two fire alarm boxes measured horizontally on the same floor?

Options:

A.

30 feet (9.1 meters)

B.

60 feet (18.3 meters)

C.

90 feet (27 meters)

D.

200 feet (61 meters)

Buy Now
Question # 12

What is the maximum extended interval allowed for equipment to get inspected?

Options:

A.

3 months

B.

6 months

C.

12 months

D.

18 months

Buy Now
Question # 13

Which two of the following are needed to perform a periodic test of a projected beam type smoke detector? (Choose two.)

Options:

A.

Blocking the transmitter

B.

Introducing smoke

C.

Using a listed test switch

D.

Using an optical filter

Buy Now
Exam Code: ITFAS-Level-1
Exam Name: Inspection and Testing of Fire Alarm Systems Level I Exam
Last Update: May 9, 2025
Questions: 85
ITFAS-Level-1 pdf

ITFAS-Level-1 PDF

$34  $84.99
ITFAS-Level-1 Engine

ITFAS-Level-1 Testing Engine

$38  $94.99
ITFAS-Level-1 PDF + Engine

ITFAS-Level-1 PDF + Testing Engine

$54  $134.99