Weekend Special Limited Time 65% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: bigdisc65

FlashArray-Implementation-Specialist Exam Dumps - Pure Storage FAIS Questions and Answers

Question # 14

In a situation where iSCSI cards need to be re-used during a controller upgrade, which is a valid transfer path?

Options:

A.

XR2 > XR3

B.

M > XR2/3

C.

M > XR2

Buy Now
Question # 15

A customer wants to expand the capacity of their FlashArray//X10 from 5/5 to 11/11. Which is the correct action to take?

Options:

A.

Evacuate and swap one pack at a time.

B.

Perform a drive-by-drive swap of the modules.

C.

Install a swing shelf with loan capacity to evacuate to.

Buy Now
Question # 16

After upgrading Purity during a new installation, which command should an Implementation Engineer run to determine what version of Purity will be loaded at the next boot of the FlashArray?

Options:

A.

purearray list --controller

B.

pureversion -a

C.

pureboot list

Buy Now
Question # 17

After an Implementation Engineer installs a new FlashArray and runs health checks, they see that Phonehome and Remote Assist are NOT working correctly.

Which outbound port needs to be open for all management ports (physical and virtual)?

Options:

A.

80

B.

443

C.

123

Buy Now
Question # 18

What are the interface names for a 4-port FC card in slot 1 in an XR2/3 array?

Options:

A.

FC0, FC1, FC2, and FC3

B.

FC4, FC5, FC6, and FC7

C.

FC5, FC6, FC7, and FC8

Buy Now
Question # 19

For FlashArray//XL, which PCIe card slot is reserved for control upgrades?

Options:

A.

5

B.

6

C.

7

Buy Now
Question # 20

A customer needs to have arrays installed and configured with ActiveCluster and ETH replication. The installation document contains 3 IP addresses. How many additional IP addresses are needed?

Options:

A.

4

B.

5

C.

6

Buy Now
Question # 21

What is the maximum number of DirectFlash Shelves supported for FlashArray//XL?

Options:

A.

2

B.

3

C.

4

Buy Now
Question # 22

If a Technical Support Engineer (TSE) is not available to perform health checks after an installation, what action should the Implementation Engineer take?

Options:

A.

Email the account team

B.

Update and close the case.

C.

Verify that Remote Assist (RA) is open and update the case.

Buy Now
Question # 23

A customer has a FlashArray X20R3 with 22/22 data packs in the chassis at 80% space usage and wishes to swap one of the data packs for a 45TB pack. What step needs to be taken to facilitate this consolidation?

Options:

A.

Send a DirectFlash Shelf without any additional capacity.

B.

Send a DirectFlash Shelf with a 63TB of temporary extra capacity.

C.

Reduce array space usage to allow for the evacuation of the 22TB packs.

Buy Now
Exam Name: Pure Certified FlashArray Implementation Specialist (FAIS) Exam
Last Update: Jul 5, 2025
Questions: 75
FlashArray-Implementation-Specialist pdf

FlashArray-Implementation-Specialist PDF

$29.75  $84.99
FlashArray-Implementation-Specialist Engine

FlashArray-Implementation-Specialist Testing Engine

$33.25  $94.99
FlashArray-Implementation-Specialist PDF + Engine

FlashArray-Implementation-Specialist PDF + Testing Engine

$47.25  $134.99